Laserfiche WebLink
<br />Page 26 <br /> <br />buildings will impose a structural load. This soil bearing issue shall be <br />addressed by the Geotechnical Engineer with the construction documents for <br />City review. <br /> <br />91. WATER SERVICE. Sheet 6 “Preliminary Utility Plan” shows a master water meter and <br />backflow preventer servicing the site. Beyond the backflow preventer, all water mains <br />and submeters shall be private with operation and maintenance to be performed by <br />the homeowner’s association. The property is currently served by a 2” potable water <br />meter (Account 13176-14000-001, Meter #68596527). If a different type of water <br />service is requested, the applicant shall terminate this service with the City’s Utility <br />Billing Division and shall disconnect the water lateral at the main in Black Avenue. <br />Fee credits will be offered for the removed meter when new water services are <br />requested. <br /> <br /> The City purchases water wholesale from Zone 7 Water Agency. Fees are due to <br />both the City of Pleasanton and Zone 7 for new connections to the pipe network. Said <br />fee amounts appear in the City’s Adopted Master Fee Schedule. For more information <br />about water usage in Pleasanton, refer to Pleasanton Municipal Code Title 14. <br /> <br /> The City’s ability to provide potable water to the proposed development at sufficient <br />pressure and volume must be confirmed by running a scenario within the City’s Water <br />Master Plan computer model operated by a City-hired consultant. The consultant will <br />run the scenario and then issue a report with their findings. The applicant shall fund <br />this effort and address any discovered network deficiencies that are directly <br />attributable to the development. <br /> (Address this condition prior to permit issuance). <br /> <br />92. FRONTAGE SIDEWALK WIDENING. The public sidewalk that fronts the property <br />along the south side of Black Avenue contains segments that have been <br />lifted/damaged by the growth of street trees. Said damage shall be addressed by <br />replacement of defective sidewalk in accordance with Pleasanton standards as part of <br />the development. The horizontal clearance around each street tree shall be sufficient <br />to allow unobstructed access by the disabled. If any portion of the sidewalk extends <br />beyond the public right-of-way line, a Public Access Easement shall be granted to the <br />City across that portion. (Address this condition prior to plan approval). <br /> <br />93. BACKFLOW PREVENTION ASSEMBLIES: Backflow preventer assemblies shall be <br />designed and installed in accordance with current City Standard Drawings 704, 705, <br />706; Pleasanton Municipal Code Chapter 14.16, State Health and Safety Code; State <br />Water Resources Control Board adopted Cross-Connection Control Policy Handbook <br />(CCCPH); and as required by the Public Works Department. Backflow Preventers <br />(BFP) shall be selected from the latest “List of Approved Backflow Prevention <br />Assemblies” available from the Foundation for Cross-Connection Control and <br />Docusign Envelope ID: 52DE2131-F0C9-4C18-86DD-6B9E7ADA8792