Laserfiche WebLink
<br /> <br /> <br />City of Pleasanton, CA (0012108.00) 2-5 Woodard & Curran, Inc. <br />Pleasanton Long-Term Sewer CIP October 6, 2025 <br />projects were included from the Energy Master Plan in the long-term CIP, but these costs were assumed to <br />be included as part of the mid- and long-term lift station rehabilitation work. <br />2.6 Generator Report (TJC) <br />A separate generator report was prepared for the City in addition to the sewer lift station condition <br />assessment. The goal of the report was to identify which pump/lift stations (including water, sewer, and <br />storm) were most critical to the City and, in turn, recommend a reliable backup power source based on each <br />asset’s priority. Priority was based on system importance with the most critical assets receiving a <br />recommendation for stationary generators located at the lift stations to allow the station to run even if <br />power was lost for up to 24 hours. Less robust systems were recommended for less critical assets. Costs for <br />these upgrades to the sewer and storm drain lift station are included in the CIP (water pump station <br />generator upgrades are captured in the water system long-term CIP). <br />2.7 Future Evaluation Efforts <br />While the physical condition of most gravity sewers can be determined with standard CCTV inspections, <br />several asset types require special considerations/techniques to determine their condition. This section <br />presents several proposed methods for the condition assessment of large diameter trunk sewer pipelines, <br />siphons, and force mains. Although these assets account for a small overall percentage of the system, their <br />operation is critical to maintaining the City’s current level of service. <br />2.7.1 Large Diameter Trunk Sewer Condition Assessment <br />The City does not currently have CCTV inspection data for their trunk sewers (considered to be any gravity <br />sewer larger than 15 inches). These pipes are primarily located upstream of EALS, LS -8, and LS-6. Trunk <br />sewers are typically more difficult to inspect than smaller diameter gravity sewers due to higher flow levels <br />in the pipe. The additional flow can obscure view of the pipe wall, potentially causing inspection to miss <br />defects in the pipe. Other issues include potential debris buildup in the pipe as grease and sediment deposit <br />along the trunk line. In order to inspect these pipes, it is recommended that trunk sewers be inspected <br />during nighttime hours, when the flow levels in the pipes are lowest, approximately 25 to 50 percent full <br />based on hydraulic modeling results. During lower flow conditions like this, standard CCTV equipment could <br />be used, and no flow bypass or flow plugs would be required. If significant flow or debris is present in the <br />pipe, optional sonar measurements could be used to get a sense of the level of debris and condition under <br />the water surface if pre-cleaning cannot remove the debris. <br />Additionally, sewer trunk manholes are recommended for detailed inspection. Sewer trunk manholes are <br />generally more prone to failure from Microbiologically Induced Corrosion (MIC) than typical gravity sewer <br />manholes due to the higher likelihood of hydrogen sulfide present in trunk sewers compared to typical <br />small diameter gravity sewers. Surface level visual observation could be used to inspect the manholes walls <br />as part of this assessment. However, surface level inspection often provides limited information on the <br />condition of the concrete in the lower sections of the trunk manholes where corrosion is more likely to be <br />visible. Therefore, a more detailed man-entry or televised inspection is recommen ded, especially if MIC is <br />noted in the pipe or manhole. It is recommended that a manhole inspection based on NASSO Manhole <br />Assessment Certification Program (MACP) level 2 inspection be performed along the trunk sewer if manhole <br />corrosion is a concern. <br />Page 224 of 323