My WebLink
|
Help
|
About
|
Sign Out
Planning Commission Agenda Packet 02252026
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2026
>
02-25
>
Planning Commission Agenda Packet 02252026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 3:39:16 PM
Creation date
2/24/2026 3:38:14 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
2/25/2026
DESTRUCT DATE
15Y
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
P25-0671 and -0672, 1252 Quarry Lane, Suite A Planning Commission <br />6 of 8 <br /> <br />Noise <br />Conditional uses must be consistent with PMC Chapter 9.04 (Noise Regulations), which are <br />designed to promote stability of existing conforming land uses and protect them from <br />inharmonious or intrusive impacts from new land uses. For industrially zoned properties, PMC <br />Chapter 9.04.050 specifically limits noise to a maximum of 75 dBA1 at any point outside the <br />property line at any time. <br /> <br />Staff finds the proposed use to be compatible with surrounding development and unlikely to <br />result in a substantial increase in ambient noise at nearby sensitive receptors. The site is <br />already influenced by existing background noise from Valley Avenue, Stan ley Boulevard, and <br />the Union Pacific rail corridor. All primary activities, including worship services, teaching, and <br />music, would occur entirely within the enclosed building and would be similar in character to <br />other commercial, educational, and assembly-type uses that have operated within the Valley <br />Business Park without reported issues. <br /> <br />The applicant has proposed operational limits and physical sound-attenuation measures to <br />further reduce potential impacts. Amplified speech and music would generally be limited to <br />Sunday mornings, weekday evenings, and occasional Saturday daytime events. T he project <br />includes professional acoustical design and installation of interior sound -absorbing wall panels <br />and batt insulation at shared and exterior walls. Newly constructed sanctuary walls are <br />specified to achieve a high Sound Transmission Class (STC) rating, with additional wall <br />assemblies and existing exterior construction providing layered attenuation. Based on the <br />applicant’s acoustical specifications, interior sound levels associated with speech and music <br />would be substantially reduced before reaching adjacent suites or the building exterior, <br />supporting compliance with the PMC’s 75 dBA exterior standard. <br /> <br />Staff also recommends conditions of approval to ensure ongoing compatibility, including: (1) <br />keeping exterior doors closed during services and events; (2) advising attendees and <br />employees to minimize outdoor noise and loitering; and (3) reserving the City’s right to <br />reevaluate the CUP and impose additional conditions if substantiated complaints occur, such <br />as limiting occupancy or hours of operation or requiring additional soundproofing. <br /> <br />With the incorporation of these operational limits, construction measures, and recommended <br />conditions, staff believes the proposed use would not create harmful noise intrusions, would <br />remain within applicable PMC noise standards, and would be compatible with existing and <br />future surrounding uses. <br /> <br /> <br /> <br /> <br /> <br />1 A-weighted decibels, a measurement of sound level that adjusts for the way the human ear perceives different <br />frequencies. Unlike raw decibel (dB) measurements, which capture all sound pressure levels equally, dBA applies <br />a filter that reduces the influence of very low and very high frequencies —where human hearing is less sensitive— <br />while emphasizing mid-range frequencies (around 250–5,000 Hz), where the ear is most responsive. This <br />makes dBA a more accurate representation of perceived loudness and the potential impact of noise on human <br />health and comfort. It is widely used in environmental noise monitoring, occupational safety (e.g., workplace <br />hearing protection requirements), and product ratings (like dishwashers, HVAC units, and vehicles). <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.