Laserfiche WebLink
<br /> <br />a. Provide Continuous Monitoring with UL 827 Compliant Central Station monitoring <br />service for Fire Alarm, supervisory, and trouble signals. <br />b. Signal Reception with an ability to receive signals from various sources (IP, cellular, <br />radio, traditional dialers). <br />c. Emergency response with an immediate verification of alarms and dispatch of emergency <br />services to local fire and/or police. <br />d. System maintenance with testing of the monitoring system (quarterly and annually) and <br />repair services. <br />e. Provide reporting with detailed logs of faults, tests, and event history. <br /> <br />Materials and Disposal Requirements <br />The Contractor shall furnish, as part of this agreement, all necessary materials, equipment, and supplies <br />required for the inspection, testing, and maintenance of fire alarm systems. <br />• All construction debris, defective parts, or waste materials shall be removed daily and disposed <br />of in accordance with all applicable federal, state, and local laws <br />• There shall be no additional charge to the City for waste removal or disposal <br />• Work sites shall be kept clean and free of hazards at all times <br /> <br />Fire Sprinkler Discharge Water <br />Prevent discharge of water from fire sprinkler system maintenance and testing activities to the storm <br />drain system. AFS water is from a potable water source and therefore contains chloramines, which are <br />toxic to aquatic organisms. To comply with Pleasanton Municipal Revised Code §9.14.120 – Reduction <br />of Pollutants in Storm Water, use the following guidelines: <br />• Do NOT discharge water from fire sprinkler testing or maintenance activities into a storm drain <br />or into an area that will discharge into a storm drain <br />• Discharge all fire sprinkler discharge water to the sanitary sewer system <br />If it is not practical or feasible to discharge to the sanitary sewer, AFS water may be discharged to a <br />landscaped area, using all of the following controls: <br /> <br />• To the greatest extent possible, a landscape area shall be found with sufficient capacity to contain <br />the AFS discharge without eroding the surface and discharging sediment across pedestrian areas <br />• The AFS discharge water shall flow through a mat containing sodium thiosulfate tablets (or <br />equivalent) before flowing to a landscaped area in case some of the water overflows to the storm <br />drain or MS4. Discharges to the storm drain or MS4 are not allowed if the AFS water contains <br />visible amounts of suspended material/dirt/oxidation. <br />• An energy dissipation device shall be employed as needed to prevent harm to the landscape and <br />prevent sediment loss and runoff to the storm drain. <br />• If AFS water contains visible amounts of suspended solids (oxidized materials/dirt/etc), fire <br />system discharge must be contained and discharged to the sanitary sewer. All AFS water must be <br />contained in an appropriate tank or tanker truck. Collected AFS discharge water shall be lawfully <br />discharged in the sanitary sewer at a rate not to exceed the hydraulic capacity or causing a <br />sanitary sewer overflow. <br />• Fire sprinkler discharge water may be released into a vegetated area under the following <br />conditions: <br />Page 288 of 846