Laserfiche WebLink
Section 7 2025 Urban Water Management Plan <br />Water Supply Reliability Assessment City of Pleasanton <br /> Public Draft | May 2026 <br /> 7-13 EKI Environment & Water, Inc. <br />Table 7-5 Single Dry Year Supply and Demand Comparison – District Total (DWR Table 7-3) <br /> 2030 2035 2040 2045 <br />(AF) (AF) (AF) (AF) <br />Supply totals 16,401 17,288 18,178 19,172 <br />Use totals 16,401 17,288 18,178 19,172 <br />Surplus/(shortfall) 0 0 0 0 <br />7.3.3 Multiple Dry Year Supply and Demand Assessment <br />Zone 7’s 2025 UWMP indicates the ability to meet retailer demands during five-year droughts beginning <br />in 2030, 2035, and 2040. However, beginning in 2045, Zone 7 is projecting a 14% shortfall for the fifth year <br />of a five-year drought. Because the City anticipates the ability to access its full GPQ of 3,500 AFY will be <br />restored through the Joint Groundwater Project, the assessment of future water supply reliability assumes <br />that the City will rely upon groundwater to meet 3,500 AFY of its potable demands in each year of a five- <br />year drought through 2045 and that the remaining balance will be met through Zone 7 supply purchases. <br />For the fifth year of a five-year drought in 2045, the projected 14% reduction in Zone 7 supply availability <br />translates to a 10% shortfall for the City. <br />In the event of a shortfall at this level, the City anticipates enacting its WSCP at Shortage Level 2 (see <br />Appendix D and Section 8), which is anticipated to fill the gap as shown in Table 7-6. <br />Table 7-6 Five Consecutive Dry Years Supply and Demand Comparison (DWR Table 7-4) <br /> Volume (AF) a <br />2030 2035 2040 2045 <br />First year <br />Supply totals 16,401 17,288 18,178 19,172 <br />Use totals 16,401 17,288 18,178 19,172 <br />Surplus/(shortfall) 0 0 0 0 <br />Second year <br />Supply totals 16,401 17,288 18,178 19,172 <br />Use totals 16,401 17,288 18,178 19,172 <br />Surplus/(shortfall) 0 0 0 0 <br />Third year <br />Supply totals 16,401 17,288 18,178 19,172 <br />Use totals 16,401 17,288 18,178 19,172 <br />Surplus/(shortfall) 0 0 0 0 <br />Fourth year <br />Supply totals 16,401 17,288 18,178 19,172 <br />Use totals 16,401 17,288 18,178 19,172 <br />Surplus/(shortfall) 0 0 0 0 <br />Fifth year <br />Supply totals 16,401 17,288 18,178 17,212 <br />Use totals 16,401 17,288 18,178 19,172 <br />Surplus/(shortfall) 0 0 0 (1,960) <br />Planned WSCP Actions <br />WSCP - supply augmentation benefit 0 0 0 0 <br />WSCP - use reduction savings benefit 0 0 0 1,960 <br />Revised Surplus/(shortfall) 0 0 0 0 <br />NOTE: <br />While this reliability assessment is prepared based on the prescribed approach in DWR’s 2025 Guidebook, the <br />City anticipates that it would implement WSCP in earlier years of drought.