My WebLink
|
Help
|
About
|
Sign Out
PC-2026-15
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2020 - PRESENT
>
2026
>
PC-2026-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2026 12:52:06 PM
Creation date
8/5/2026 12:48:39 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
6/24/2026
DESTRUCT DATE
PERMANENT
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
330 Land Company, LLC Arroyo Lago <br />9785.004.001 Design-Level Geotechnical Report <br /> <br /> <br /> Page | 23 April 16, 2024 <br />Latest Revision October 31, 2025 <br />PERIOD <br />(seconds) <br />PSEUDO-SPECTRAL ACCELERATION (g) <br />MCER DE <br />1.5 1.1 0.74 <br />2 0.88 0.59 <br />3 0.63 0.42 <br />4 0.45 0.3 <br />5 0.34 0.23 <br />7.5 0.19 0.12 <br />10 0.11 0.076 <br /> <br />TABLE 6.3-2: 2025 CBC Seismic Design Parameters, Latitude: 37.6786 Longitude: -121.8563 <br />PARAMETER VALUE <br />Site Class D <br />Mapped MCER Spectral Response Acceleration at Short Periods, SS (g) 1.91 <br />Mapped MCER Spectral Response Acceleration at 1-second Period, S1 (g) 0.76 <br />MCER Spectral Response Acceleration at Short Periods, SMS (g) 1.9 <br />MCER Spectral Response Acceleration at 1-second Period, SM1 (g) 1.7 <br />Design Spectral Response Acceleration at Short Periods, SDS (g) 1.27 <br />Design Spectral Response Acceleration at 1-second Period, SD1 (g) 1.13 <br />MCEG Peak Ground Acceleration adjusted for site Class effects, PGAM (g) 0.67 <br />Long period transition-period, TL (sec) 8 <br /> <br />6.4 EXTERIOR FLATWORK <br /> <br />Exterior flatwork includes items such as concrete sidewalks, steps, and outdoor courtyards <br />exposed to foot traffic only. Provide a minimum section of 6 inches of concrete over 6 inches of <br />aggregate base. Finished subgrade and aggregate base should be compacted in accordance with <br />Section 5.6. Flatwork edges should be thickened to at least below the aggregate base section to <br />help control moisture variations in the subgrade and place reinforcement within the middle third <br />of the slab to help control the width and offset of cracks. Control and construction joints should be <br />in accordance with current Portland Cement Association Guidelines. <br /> <br />7.0 RETAINING WALL RECOMMENDATIONS <br /> <br />7.1 LATERAL SOIL PRESSURES <br /> <br />Unrestrained walls constructed on level and sloped foreground should be designed for active <br />lateral fluid pressure as provided below. <br /> <br /> TABLE 7.1-1: Active Earth Pressure <br />BACKFILL SLOPE CONDITION ACTIVE PRESSURE (pcf) <br />Level 50 <br />3:1 60 <br />2:1 70 <br /> <br />The above lateral earth pressures assume level backfill conditions and sufficient drainage behind <br />the walls to prevent any buildup of hydrostatic pressures from surface water infiltration and/or a <br />rise in the groundwater level. If adequate drainage is not provided, we recommend that an
The URL can be used to link to this page
Your browser does not support the video tag.