My WebLink
|
Help
|
About
|
Sign Out
PC-2026-15
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2020 - PRESENT
>
2026
>
PC-2026-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2026 12:52:06 PM
Creation date
8/5/2026 12:48:39 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
6/24/2026
DESTRUCT DATE
PERMANENT
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
330 Land Company, LLC Arroyo Lago <br />9785.004.001 Design-Level Geotechnical Report <br /> <br /> <br /> Page | 24 April 16, 2024 <br />Latest Revision October 31, 2025 <br />additional equivalent fluid pressure of 40 pcf be added to the values recommended above for both <br />restrained and unrestrained walls. Damp-proofing of the walls should be included in areas where <br />wall moisture would be problematic. <br /> <br />7.2 RETAINING WALL FOOTINGS <br /> <br />Site retaining walls can be supported on footings or drilled piers. For footings, passive resistance <br />acting on foundations and shear keys may be assumed as 300 pcf, provided that the area in front <br />of the retaining wall is level for a distance of at least 10 feet or three times the depth of foundation <br />and shear key, whichever is greater. The upper 1 foot of soil should be excluded from passive <br />resistance computations unless it is confined by pavement or a concrete slab. <br /> <br />The friction factor for sliding resistance may be assumed as 0.30. It is recommended that retaining <br />wall footings be designed using an allowable bearing pressure of 2,500 psf in firm native materials <br />or engineered fill. The footings should be at least 18 inches below lowest adjacent grades. <br /> <br />7.3 RETAINING WALL DRAINAGE <br /> <br />Either graded rock drains or geosynthetic drainage composites should be constructed behind the <br />retaining walls to reduce hydrostatic lateral forces. For rock drain construction, we recommend <br />two types of rock drain alternatives. <br /> <br />1. A minimum 12-inch-thick layer of Class 2 Permeable Filter Material (Caltrans Specification <br />68-2.02F) placed directly behind the wall, or <br />2. A minimum 12-inch-thick layer of washed, crushed rock with 100 percent passing the ¾-inch <br />sieve and less than 5 percent passing the No. 4 sieve. Envelop rock in a minimum 6 -ounce, <br />non-woven geotextile filter fabric. <br /> <br />For both types of rock drains: <br /> <br />1. The rock drain should be placed directly behind the walls of the structure. <br />2. The rock drains should extend from the wall base to roughly 12 inches below soil grade at the <br />top of the wall. <br />3. A minimum 4-inch-diameter perforated pipe (SDR 35 or Schedule 40) with glued joints and <br />end caps should be placed at the base of the wall, inside the rock drain, with perforations <br />placed down. <br />4. The pipe should be placed at a gradient of at least 1 percent if placed behind the footing to <br />direct water away from the wall by gravity to a drainage facility. Alternatively, the pipe can be <br />placed directly on top of the footing, if pre-approved by ENGEO. <br /> <br />We should review and approve geosynthetic composite drainage systems prior to use. <br /> <br />7.4 WALL BACKFILL <br /> <br />Backfill behind the retaining walls should be placed and compacted in accordance with <br />Section 5.6. Use light compaction equipment within 5 feet of the wall face. If heavy compaction <br />equipment is used, the walls should be temporarily braced to avoid excessive wall movement. <br />
The URL can be used to link to this page
Your browser does not support the video tag.