330 Land Company, LLC Arroyo Lago <br />9785.004.001 Design-Level Geotechnical Report <br /> <br /> <br /> Page | 24 April 16, 2024 <br />Latest Revision October 31, 2025 <br />additional equivalent fluid pressure of 40 pcf be added to the values recommended above for both <br />restrained and unrestrained walls. Damp-proofing of the walls should be included in areas where <br />wall moisture would be problematic. <br /> <br />7.2 RETAINING WALL FOOTINGS <br /> <br />Site retaining walls can be supported on footings or drilled piers. For footings, passive resistance <br />acting on foundations and shear keys may be assumed as 300 pcf, provided that the area in front <br />of the retaining wall is level for a distance of at least 10 feet or three times the depth of foundation <br />and shear key, whichever is greater. The upper 1 foot of soil should be excluded from passive <br />resistance computations unless it is confined by pavement or a concrete slab. <br /> <br />The friction factor for sliding resistance may be assumed as 0.30. It is recommended that retaining <br />wall footings be designed using an allowable bearing pressure of 2,500 psf in firm native materials <br />or engineered fill. The footings should be at least 18 inches below lowest adjacent grades. <br /> <br />7.3 RETAINING WALL DRAINAGE <br /> <br />Either graded rock drains or geosynthetic drainage composites should be constructed behind the <br />retaining walls to reduce hydrostatic lateral forces. For rock drain construction, we recommend <br />two types of rock drain alternatives. <br /> <br />1. A minimum 12-inch-thick layer of Class 2 Permeable Filter Material (Caltrans Specification <br />68-2.02F) placed directly behind the wall, or <br />2. A minimum 12-inch-thick layer of washed, crushed rock with 100 percent passing the ¾-inch <br />sieve and less than 5 percent passing the No. 4 sieve. Envelop rock in a minimum 6 -ounce, <br />non-woven geotextile filter fabric. <br /> <br />For both types of rock drains: <br /> <br />1. The rock drain should be placed directly behind the walls of the structure. <br />2. The rock drains should extend from the wall base to roughly 12 inches below soil grade at the <br />top of the wall. <br />3. A minimum 4-inch-diameter perforated pipe (SDR 35 or Schedule 40) with glued joints and <br />end caps should be placed at the base of the wall, inside the rock drain, with perforations <br />placed down. <br />4. The pipe should be placed at a gradient of at least 1 percent if placed behind the footing to <br />direct water away from the wall by gravity to a drainage facility. Alternatively, the pipe can be <br />placed directly on top of the footing, if pre-approved by ENGEO. <br /> <br />We should review and approve geosynthetic composite drainage systems prior to use. <br /> <br />7.4 WALL BACKFILL <br /> <br />Backfill behind the retaining walls should be placed and compacted in accordance with <br />Section 5.6. Use light compaction equipment within 5 feet of the wall face. If heavy compaction <br />equipment is used, the walls should be temporarily braced to avoid excessive wall movement. <br />