My WebLink
|
Help
|
About
|
Sign Out
16 ATTACHMENTS
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2007
>
030607
>
16 ATTACHMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2007 8:45:53 AM
Creation date
2/28/2007 4:30:56 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
3/6/2007
DESTRUCT DATE
15 Y
DOCUMENT NO
16 Attachments
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project No. JB-569 <br />20 June 2006 <br />Page 9 <br />or equivalent pipe installed on a bed of approximately 3 inches of drain rock. <br />Class 2 Permeable drain rock is and acceptable equivalent for drain rock and <br />geotextile. The subdrain must be placed at the heel (rear) of the keyway/bench <br />with perforations placed downward. The subdrain should be extended to an <br />acceptable outlet using unperforated pipe outside of the drain rock. All subdrain <br />and outlet drain pipe must be placed to fall at least 1 percent. <br />Fill placed within the keyway must be compacted to a minimum of 95 percent <br />relative compaction at a minimum of 3 percent over optimum moisture content. <br />Fill placed above the keyway or above benched areas must be compacted to a <br />minimum of 90 percent relative compaction. <br />The gradient of the exposed outboard surface of the fill must not exceed 2H:1 V. <br />Additional recommendations may be made for fill slope construction depending <br />on the soil conditions encountered. <br />6.2 Foundations <br />6.2.1 Conventional Foundation System <br />If the earthwork recommendations included in this report are complied with, the <br />proposed private residences may be supported by conventional foundations <br />established on compacted, engineered fill. Settlement of the proposed structures, <br />supported as recommended, should be less than 1 inch. Recommendations for <br />footing depths and foundation details are included in Table 3. <br />The excavations for footings must be cleaned of all loose materials and debris, <br />and moistened prior to placement of concrete. All footing excavations must be <br />observed by our representative to verify the condition of the bearing material. If <br />any localized areas of loose or soft undesirable subsoil are observed in footing <br />excavations, the excavation for the footings must be over-excavated to firm soil <br />and backfilled with compacted fill under the observations and testing of our <br />representative. <br />All footings should be reinforced with top and bottom reinforcement to provide <br />structural continuity and to permit spanning of local irregularities. The <br />reinforcement of the footing should be designed by a structural engineer. <br />If a different type of foundation system is desired, this office should be called for <br />supplemental recommendations. Such recommendations will be presented as an <br />addendum to this report. <br />ire Korbmacher Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.