My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.20.027 <br />on-site assembly, where listed for <br />such use, shall be permitted for on- <br />site interconnection of modules or <br />other array components. Such fittings <br />and connectors shall be equal to the <br />wiring method employed in insula- <br />tion, temperature rise, and fault- <br />current withstand, and shall be capa- <br />ble of resisting the effects of the <br />environment in which they are used. <br />located behind modules or panels <br />shall be installed so that the wiring <br />contained in them can be rendered <br />accessible directly or by displace- <br />ment of a module(s) or panel(s) <br />secured by removable fasteners and <br />connected by a flexible wiring sys- <br />tem. <br />V. Grounding <br />690.33 Connectors. 690.41 System Grounding. <br />The connectors permitted by Article <br />690 shall comply with 690.33(A) <br />through (E). <br />(A) Configuration. The connectors <br />shall be polarized and shall have a <br />configuration that is non-interchange- <br />able with receptacles in other electri- <br />cal systems on the premises. <br />(B) Guarding. The connectors shall <br />be constructed and installed so as to <br />guard against inadvertent contact <br />with live parts by persons. <br />(C) Type. The connectors shall be of <br />the latching or locking type. <br />For a photovoltaic power source, one <br />conductor of a two-wire system with <br />a system voltage over 50 volts and <br />the reference (center tap) conductor <br />of a bipolar system shall be solidly <br />grounded or shall use other methods <br />that accomplish equivalent system <br />protection in accordance with <br />250.4(A) and that utilize equipment <br />listed and identified for the use. <br />690.42 Point of System Grounding <br />Connection. <br />The do circuit grounding connection <br />shall be made at any single point on <br />the photovoltaic output circuit. <br />(D) Grounding Member. The ground- FPN: Locating the grounding con- <br />ing member shall be the first to make nection point as close as practica- <br />and the last to break contact with the ble to the photovoltaic source <br />mating connector. better protects the system from <br />voltage surges due to lightning. <br />(E) Interruption of Circuit. The con- <br />nectors shall be capable of interrupt- 690.43 Equipment Grounding. <br />ing the circuit current without hazard <br />to the operator. Exposed non-current carrying metal <br />parts of module frames, equipment, <br />690.34 Access to Boxes. and conductor enclosures shall be <br />grounded in accordance with 250.134 <br />Junction, pull, and outlet boxes or 250.136(A) regardless of voltage. <br />710-25 (Pleasanton April 2003) <br />
The URL can be used to link to this page
Your browser does not support the video tag.