My WebLink
|
Help
|
About
|
Sign Out
1999 MAY
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
1999 MAY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:08:10 PM
Creation date
7/13/2007 3:20:01 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
5/1/1999
DOCUMENT NO
1999 MAY
DOCUMENT NAME
SUPPLEMENT NO 8
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
380
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.24.120 <br />nized standards, if any, ap- <br />proved by the Fire Chief, and <br />shall have welded connections <br />compatible with the regulated <br />material throughout unless an <br />exhausted enclosure is provided. <br />[ii] Material which is not <br />compatible with ferrous piping <br />may be installed in non-ferrous <br />piping approved by the Fire <br />Chief. <br />[iii] Where connections <br />other than welded connections <br />meet appropriate nationally <br />recognized industry standards, if <br />any, a person responsible for a <br />facility may seek an exception <br />from the Fire Chief, by filing a <br />request for exception with the <br />Fire Chief, which shall docu- <br />ment the standards and reason <br />for the exception. <br />(2) Local Gas Shut-Off. <br />[i] Manual activation con- <br />trols shall be provided at loca- <br />tions near the point of use and <br />near the source, as approved by <br />the Fire Chief. <br />[ii] The Fire Chief may <br />require additional controls at <br />other places, including, but not <br />limited to, the entry to the <br />building, the area in the build- <br />ing where regulated materials <br />are stored or used, and emer- <br />gency control stations. <br />[iii] Manually activated <br />shut-off valves shall be of "fall <br />safe to close" design. <br />(3) Emergency Power. Emer- <br />gency power shall be provided for: <br />[i] Exhaust ventilation, <br />including the power supply for <br />treatment systems. <br />[ii] Gas-detection systems. <br />[iii] Emergency building <br />alarm systems and fire detection <br />alarm transmission to an ap- <br />proved central station. <br />[iv] Temperature-control <br />systems which comply with the <br />Fire Code. <br />(4) Excess Flow Control. <br />[i] Portable tanks and <br />cylinders shall be provided with <br />excess flow control. <br />[ii] Valves shall be perma- <br />nently marked to indicate the <br />maximum design flow rate. <br />(5) Gas Detection. A continuous <br />gas-detection system (in accor- <br />dance with the 1994 Ed. Uniform <br />Fire Code, Section 8003.3.1.6) <br />shall be provided to detect the <br />presence of gas at or below the <br />permissible exposure limit. The <br />detection system shall initiate a <br />local alarm and transmit a signal <br />(Pleasanton 5-99) 710-24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.