submitted in writing and approved prior to the commencement of <br />construction. <br /> <br />F. Domestic Water: <br /> <br /> 1. Design Criteria: The onsite domestic water service must <br /> be installed as shown on City Standard Drawing No. BP-1A <br /> when there is an onsite fire service system. The pipe type <br /> and appurtenances shall be as allowed in IAPMO IS 7-81 and <br /> 8-81 of the UPC. Depth of pipe below subgrade and finished <br /> grade must meet minimums and maximums specified by the pipe <br /> manufacturer, and as specified in these sections of the UPC. <br /> <br /> The pipe type and size do not need to be specified on the <br /> plans for that portion of the system between the meter and <br /> the building. The pipe must be labeled "water service" and <br /> shown in its approximate location to be installed. Flow <br /> line elevations need not be shown. <br /> <br /> For that portion of the service between the water main and <br /> the meter, the pipe size must be indicated. Additionally, <br /> the meter location and size must be indicated. <br /> <br /> A reduced pressure backflow prevention device must be <br /> installed on the building side of the domestic meter. This <br /> device must be above ground and shall be installed as shown <br /> on City Standard Drawing No. BP-6. The type or size need <br /> not be indicated but must be specified to be one of the <br /> types listed on City Standard Detail No. BP-7 to comply with <br /> types indicated as allowable on said City Standard Drawing. <br /> <br />G. Site Lighting: The locations of freestanding site lights <br />must be shown on the Grading and Utility Plan in order that any <br />conflicts with other utility conduits are easily recognizable. <br /> <br />Lights must be designed to direct light onto the site, with light <br />shining offsite kept to a minimum. Minimum light levels must be <br />achieved at all locations onsite to the satisfaction of the <br />Police Department. <br /> <br />H. Notes: Notes must be shown on the Grading and Utility Plan <br />which address the following: <br /> <br /> 1. Grading and paving must be done in compliance with <br /> recommendations listed in the Soils Investigation. <br /> <br /> 2. Responsibility of the Contractor to confirm the <br /> location of all existing underground utilities prior to the <br /> <br /> 20 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.